Roll cap system on a damp proof system

See chapter 4 for standard and alternative built ups.

Damp proof façade built up with NedZink roll cap system.

The construction of the façade is built up as follows, beginning on the inside

1. Building structure
2. Damp control course μd ≥ 150 m
3. Insulation layer, according to thermal requirements
4. Wooden substructure
5. Separating layer
6. Roll cap system

Roll cap system details damp proof vertical bay.